ATEN Technology CS-1708 Manuale Utente Pagina 20

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 19
Port ID Numbering
Each CPU port on a Master View installation is assigned a unique Port ID. The Port
ID is made up of two parts: a two-digit Station Number, and a two-digit Port Number:
w The Station Number - reflects the switch’s position in the daisy chain
sequence. This corresponds to the number displayed on the front panel
Station ID LED.
w The Port Number - reflects the port on the Station that the computer is
connected to.
w The Station Number precedes the Port Number.
w Station and Port numbers from 1 - 9 are padded with a preceding zero, so
they become 01 - 09.
For example, a computer attached to Port 6 of Station 12 would have a Port ID
of: 12-06.
Powering Off and Restarting
If it becomes necessary to Power Off one of the switches, unplug its power adapter
cable from the power jack.
Before starting it back up you must do the following:
1. Shut down all the computers that are attached to it.
Note: Unplug the power cords of any computers that have the Keyboard
Power On function. Otherwise, the switch will still receive power
from the computers.
2. Wait 10 seconds, then plug the power adapter back in.
3. After the CS-1708 / CS-1716 is up, Power On the computers.
Note: If you have shut down more than one Station, power up the highest
Station first and work your way down to the lowest one.
2004-04-27
CS-1708 / CS-1716 User Manual
14.
Vedere la pagina 19