Clear Login Information
If you are unable to perform an Administrator login (because the Username and
Password information has become corrupted, or you have forgotten it, for exam-
ple), you can clear the login information with the following procedure:
1. Power off the switch and remove its housing.
2. Short the jumper labeled Default Password at the right front of the switch’s
main board.
3. Power on the switch.
When you power the switch on, the following message appears on the LCD
display:
USERNAME AND PASSWORD INFORMATION HAS BEEN CLEARED.
PLEASE POWER OFF THE SWITCH, REMOVE THE JUMPER, CLOSE THE
CASE, THEN RESTART.
4. After you start back up, the OSD login function acts exactly the way it did
the first time the switch was run (see p. 1-23) and you can reset passwords
for the Administrators and Users.